Welcome to visit Scientia Silvae Sinicae,Today is

Scientia Silvae Sinicae ›› 2012, Vol. 48 ›› Issue (4): 75-80.doi: 10.11707/j.1001-7488.20120412

Previous Articles     Next Articles

Deposition Effects of Electrostatic and Non-Electrostatic Aerial Spray

Shu Chaoran1, Pan Hongyang1, Zhou Hongping2, Zhan Min3, Mei Aihua4, Ru Yu2, Jia Zhicheng2, Chen Guofa1   

  1. 1. General Station of Forest Pest Management of State Forestry Administration Shenyang 110034;2. Nanjing Forest University Nanjing 210037;3. Shenyang Agricultural University Shenyang 110161;4. Jingzhou Station of Forest Pest Control and Quarantine of Hubei 434100
  • Received:2010-07-05 Revised:2010-11-22 Online:2012-04-25 Published:2012-04-25

Abstract:

In this study, we compared the aerial electrostatic spray with non-electrostatic spray by helicopter R44 and fixed-wing aircraft Y5B equipped with an own-made aerial electrostatic spraying system. The results showed that the spray deposits on targets and leaves of tree crowns were notable enhanced comparing with the non-electrostatic and conventional aerial spray. The spray deposits were fine, uniform and the densities were 1.0~1.75 times higher than the non-electrostatic spray. Deposit rate of the electrostatic spray on the backs of leaves by helicopter R44 was 2.15 times of the non-electrostatic, and 3.31 times of the conventional aerial spray. The deposit rate of the electrostatic spray on the backs of leaves by the Y5B was 2.38 times of the non-electrostatic, and 3.44 times of the conventional aerial spray.

Key words: aerial electrostatic spray, non-electrostatic spray, spray deposit

CLC Number: